Model 2618P PCM Frame Validation System

Product Support

 

 

 

System Manual

Datasheet

Technical Specs

 

Overview

 

Is your PCM data being decrypted correctly?  Does the stream you are receiving have the frame length and sync pattern you expected?  Are your digital recorders operating correctly?  Is your data signal noisy or clean?  The Model 2618P PCM Frame Validation System will monitor as many as eight independent streams, providing a quick visual indication of the signal quality of your PCM data and verification that the received data corresponds to the expected frame characteristics.

 

The 2618P accepts clock and data from PCM decryptors or Bit Synchronizers (up to eight) and bright LED indicators on the unit’s front panel indicate the data quality of each stream.  At the same time, each stream is converted to a randomized NRZ signal for input to a downstream processor.  A log file is also generated that records the system setup, plus time annotated frame status that can be imported into Excel or other applications for inclusion in mission reports.

 

Wizard software, which can be run on any Windows computer, guides you through the simple setup procedure to create or modify mission configurations.  A USB flash drive transports the setup to the 2618P.  Once the configuration is downloaded, the data monitoring and logging operation automatically starts, so virtually no additional operator action is required.  At the end of a mission, a simple press of a button uploads the log file to a flash drive.

 

The 2618P is a 1U rack-mountable unit..

 

System Software

A Frame Validation Wizard program is used to produce setup files that control the Acroamatics Model 2618P Frame Validation System. The software that runs on the Model 2618P reads setup files from USB flash memory sticks plugged into its USB connector. These setup files must be produced with the Frame Validation Wizard program running on some other computer.

Technical Specs

INPUT

Sources

Eight channels, each accepting RS-422 differential 0° clock & NRZ data

Impedance

120Ω input impedance, TTL compatible

Bit Rate

Up to 20 Megabits per second

Polarity

Programmable, with automatic polarity correction

Frame Length

 Programmable, 16 to 16384 bits

SYNCHRONIZATION

Mainframe Sync

Provides for programmable sync pattern and mask, complement pattern recognition, and variable length frame decommutation. Pattern length up to 64 bits.

Alternate Complement Sync

Synchronizes to formats in which the minor frame sync pattern is complemented on alternate frames

Complement Frame Sync

Synchronizes to formats that complement the minor frame sync pattern at a major frame rate

Automatic Polarity Inversion

Input polarity is inverted when two consecutive complemented sync patterns are found.

Sync Modes

Fixed, Adaptive, and Burst

Sync Strategy

Search, Verify, and Lock

Sync Error Tolerance

0 to 15 errors, programmable

Sync Slip Window

0, ±1, ±2, & ±3 bits, programmable

Data Polarity

 Normal, Inverted, and Automatic detection

Clock Rate Monitor

A programmable delay counter is provided to return the synchronizer to Search if the clock input is lost.

OUTPUT

Output Signals

8 RNRZ-L Single ended outputs, one channel per input stream

PHYSICAL

Format

1U - 22" Slides included

Weight

Approx 16 lbs.

Power Requirements

115/230 VAC 6-50 Hz, 3A Max

Dimensions

17" X 19" x 1.75" (W x D x H)

Temperature

Operating 0 to +40°C, non-operating –40 to +86°C

Relative Humidity

Up to 90% non-condensing

Shock

Operating 6G, Non-operating 25G

Vibration

Operating 0.5G, 5 to 2000Hz, Non-Operating 1.2G, 5 to 500Hz